HYC.AZR.01K.KIT.003 Networked. Automation PLC remote controlled hydrogen measurements.
Hycal 1000
'All of the functionality of Hycal Mk4, but with added features'New system-level features
Technical specifications
Probe longevity
Response time
Operating expense
Gateway
| Parameter | Specification |
| Unit of measurement | ml/100g (@ 20°C and 1 atm) (milliliter of hydrogen per 100 grams of liquid aluminium ) |
| Sensor type | Electrochemical. Solid-state reference |
| Reproducibility | ±0.01 ml/100g or 3% of hydrogen concentration |
| Response time | Initial result: 5 minutes typically. Subsequent response: < 5 seconds |
| Temperature of operation | 620°C to 800°C |
| Analyser | 400 (W) x 400 (H) x 200 (D) mm. / 16 kg. |
| Probe | Standard length: 800mm. Maximum depth of immersion: 300mm Diameter: 6mm |
| Probe cable (std) | 3000mm |
| Refillable gas bottle (300ml) | Dry argon or nitrogen. Max fill pressure: 120 bar |
| Thermocouple | Type K |
| Specified limits of error | 1.1 deg C or 0.4% - whichever the greater |
| Power supply (external unit) | AC 85 - 265 V, 47 - 63 Hz |
| Typical power consumption | < 10 W |
| Max. power consumption | 210 W |
| Battery chemistry | Lithium ion |
| Battery life | 8 - 14 hours (depending on screen brightness) |
| Screen lighting | LED |
| Screen resolution | 800 x 480 WVGA, TFT colour LCD |
| Screen size | 7' (177mm) diagonal |
| Touch screen type | Analogue-resistive with 4H hardness |
| Ethernet interface | 10/100 Base-T, RJ45 |
| Communication protocol | MODBUS TCP |
| USB | 2.0 full-speed (Type A) |
| Operating Temperature | 0 - 60 deg C |
| Humidity | 5 - 95% non-condensing |
Hycal 1000 offers all of the functionality of the portable Hycal Mk4 but in addition it also includes:
Whilst possible to be used as a portable (albeit heavier) device for example mounted on a cart, it has been designed as a fixed panel device particularly suited for PLC network integration where the ultimate in automation and data management is required.
Hycal Probe Actuator located above the trough immediately prior to the casting table allows full automation and enables the entire cast to be monitored for dissolved hydrogen.
The measurement and control of hydrogen during continuous casting operations such as wire production is a critical part of the process.
Hydrogen related defects may compromise the structural integrity, mechanical properties, and electrical properties, potentially leading to catastrophic failures in critical applications. By accurately measuring and controlling the hydrogen content throughout the casting process, manufacturers can mitigate these risks, enhance the material's properties, and produce high-quality aluminum castings that meet stringent industry standards.
A Low Pressure Die Casting (LPDC) furnace has the additional complexity of being a sealed environment so that air pressure can be applied to force the aluminium up the riser tube into the mould above.
Hycal is unique in its ability to measure permanently in this environment by sealing to a custom flange plate with a compression fitting.
High Pressure Die Casting (HPDC) is generally thought not to suffer the same level of issues with hydrogen porosity compared to other castings methods. However, it remains necessary to control the hydrogen level as it can still have an influence of the mechanical properties such as tensile strength.
Hycal is unique in its ability to measure permanently in real-time within the degassing furnace, transfer ladle and also at the holding well at the HPDC furnace
The graph below shows a 'gassing-up' process followed by degassing treatment, verified finally by a static measurement.
The ability to control hydrogen content in the aluminium is unique to Hycal for the following reasons:
Measuring hydrogen content in the process of gravity casting aluminum is paramount to ensuring the quality and integrity of the final product. Hydrogen, when present in excessive amounts, can lead to severe defects like porosity and gas-related defects in castings.
These defects compromise the structural integrity, mechanical properties, and overall performance of the aluminum component, potentially leading to catastrophic failures in critical applications. By accurately measuring and controlling the hydrogen content throughout the casting process, manufacturers can mitigate these risks, enhance the material's properties, and produce high-quality aluminum castings that meet stringent industry standards.
This precision not only ensures the safety and reliability of the final product but also plays a pivotal role in reducing waste and optimizing production efficiency, making hydrogen content measurement an indispensable aspect of gravity casting aluminum.
Typically, the hydrogen content of the aluminium would be measured during or just after the degassing treatment or at the holding furnace immediately prior to casting. However, due to the speed at which Hycal is able to reach equilibrium, it is also uniquely possible for Hycal to measure the hydrogen content directly within the mould itself, thereby providing a dissolved hydrogen measurement for an individual casting.